Logger Script Kaelus Test & Measurement and RF Conditioning Products | Kaelus ::NUBICOM::
top
New Products

  • 개요 및 주요특징
  • 기술 사양
  • 주문 정보
  • 문서 자료

TWIN TMA 1800

A full band 1800MHz tower mounted amplifier with good noise figure performance, the Kaelus TMA2036 improves uplink gain thereby increasing site coverage and capacity in cellular networks.

주요특징

  • Full band 1800MHz
  • High linearity and low noise performance
  • Fail safe bypass mode with lightning protection
  • AISG and current dump compatible hardware and software configuration using AISG "personality" upload


기술 사양

DOWNLINK (TX) PATH
Passband 1805 - 1880MHz
Return loss 18dB minimum (VSWR <1.3:1)
Insertion loss 0.6dB typical
Group delay variation 5ns maximum (200kHz) | 30ns maximum (4MHz)
Maximum input power with no damage 150W (average) / 1.5kW (PEP)



UPLINK (RX) PATH
Passband 1710 - 1785MHz
Nominal gain 12dB typical
Gain variation over frequency, temperature ±1dB maximum
Noise figure 1.2dB typical
Return loss 18dB minimum operating, 14dB minimum in bypass
Bypass loss 2dB typical
Group delay variation 5ns maximum (200kHz) | 30ns maximum (4MHz)
Output IP3 +30dBm typical



ELECTRICAL
Impedance 50ohms
Intermodulation products -153dBc maximum at antenna port, 2 x 20W carriers



POWER SUPPLY AND ALARM (CURRENT WINDOW ALARM MODE, DEFAULT)
Current window alarm mode (CWA) is the default TMA operating mode and can be configured to specific customer requirements. The generic personality (F00V1) is configured so that both channels are independently powered and monitored via the respective BTS port. The BTS port sinks additional current to indicate an alarm state in its uplink path. Normal operating and alarm current values are configured independently and are alterable via a field-loadable personality file.
DC supply voltage +8V to +30V DC, negative ground
DC supply voltage via BTS-RF cable Each BTS port powered individually (programmable)
DC supply current, normal mode 100mA typical, 120mA maximum (programmable with two BTS ports powered
DC supply current, alarm mode 200mA typ per port (programmable)
DC supply current, alarm mode programmable range 150-250mA, with 100mA normal operating current



AISG MODE OF OPERATION (AUTO SELECTED ON VALID AISG 2.0 FRAMES)
AISG signals can be applied to either BTS1 or BTS2 port. The TMA unit switches to AISG mode when valid frames are detected on one of the BTS ports. Both LNA’s take DC power from the port with AISG frames or, if DC is present on both ports, both channels supply equal power to the TMA.
DC supply voltage +8V to +30V DC
AISG version 2.0 (1.1 optional)
Supply current, AISG mode 55mA at 30V, 135mA at 12V
Voltage drop, BTS to AISG port 1.5V maximum at 2A
AISG connector, current rating IEC60130-9, 8-pin female, < 4A peak, 2A continuous, pin 6
Field firmware upgradable Yes



ENVIRONMENTAL
For further details of environmental compliance, please contact Kaelus.
Temperature range -40º to +65ºC | -40º to +149ºF
Ingress protection IP67
Altitude 2,600m | 8,530.2ft max
Lightning protection IEC61312-1, RF: ±5kA maximum (8/20us), AISG: ±2kA maximum (8/20us)
MTBF 1.000,000 (hours)
Compliance EMC:EN301 489, ETSI EN 300 019 class 4.1, RoHS



MECHANICAL
Dimensions H x D x W 270 x 73 x 200mm | 10.63 x 2.87 x 7.87in (excluding connector and mounting bracket)
Weight 6kg | 13.2lbs
Finish Painted, light grey (RAL7035)
Connectors DIN 7-16 (F) x 4 long neck, AISG (F) x 1
Mounting Pole/wall bracket supplied with two metal clamps 45-178mm diameter poles

주문 정보

Part Number Description
xx Denotes customized CWA configurations
TMA2036F00V1-1 Twin TMA, 1800 full band, dual duplex, with AISG configured with generic CWA configuration
TMA2036FxxV1-1 Twin TMA, 1800 full band, dual duplex, with AISG


ELECTRICAL BLOCK DIAGRAM



MECHANICAL BLOCK DIAGRAM

문서 자료

제목 다운받기
TMA2036F00V1-1 데이터시트 다운로드
  • 가족친화우수기업
  • 청년친화 강소시업
사업자등록번호 : 220-86-72761대표이사 : 신동만대표전화 : 070-7872-0701팩스 : 02-2167-3801
(우)07299 서울특별시 영등포구 경인로 775 (문래동 3가, 에이스하이테크시티 3동 2층)